Atomic Absorption Spectrophotometer TRAS-701is completely controlled by a computer. It has a fully automatic control system with advanced temperature control technology of a graphite furnace. With a wavelength range of 190 to 900 nm. Providing a spectral bandwidth of 0.1, 0.2, 0.4, 1.0, and 2.0 nm. The setting of the background deduction method. The fast heating capacity can improve the elements' flexibility even more. . It presents the hollow cathode lamp in its operational state. It is a safe, dependable, and convenient flame system with a multi-functional software workstation.

Wavelength range  190 to 900 nm
Spectral bandwidth 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Accuracy of the wavelength ±0.15 nm
Receptivity of the wavelength  ≤0.04 nm
Baseline stability ≤0.002A/30 min (Cu)
Characteristic viscosity 0.02 μg/ml/1% (Cu)
Checking limit 0.004 μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/ mm
Inflamer All-metal titanium burner
Atomizer  Effective glass atomizer
Lamp stand 8
D2 background correction ability When the background is 1 A, the background ability should be deducted not less than 50 times, self-absorption background deduction method
Size  700 mm×550 mm×450 mm  
weight 75 Kg
Power source 220V±22V AC
Flame System 100 mm, ≤0.006 A/30 min, ≤0.025 μg/ml/1%, ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008 μg/ml), Can Automatically cut off the gas when The pressure is not enough, The power is off, flameout and unconformity of the burner.
Graphite furnace 3000 ℃, ≥2000 ℃/S, Cd≤0.5×10 to12 g
 Cu≤0.5×10 to 11 g, Cu≤3% Cd≤3 %, 550 mm×450 mm×300 mm  65 Kg
Power source and power 220 V±22 V  AC  7000 W
  • The hollow cathode lamp's operational state
    Wavelength searching and peak search are completely automatic
    The integrated floated optical platform design improves the optical system's shock resistance and stability when using the optical signal for an extended period
    Eight light stands can be changed automatically while simultaneously preheating and optimizing the eight lights
    Adjustable position: It can automatically set the front and rear positions, as well as the best height for the flame burner
    The setting of the background deduction method
    Background self-absorption and the Deuterium lamp
    Data processing, super-strong database with over 500 data self-storage and cut-off storage functions
    can hold the analysis results in form of a Spreadsheet, and the test procedure and result can be called at random
    The flame results demonstrated and the emissions technique are two methods for measuring
    Result printing: parameter printing, data result printing, and diagram printing
    It has fully automatic controlled, with the help of the software
    The selection of lamp elements, Front-to-rear lifter adjustment (up/down)
    Re-adjustment of optical energy, selecting the slit, Determination of wavelength scanning and peak searching, sixth, choosing an atomizer
    Full safety chain protection, warning and automatic protection against incorrect burner, gas leakage, air under voltage, and abnormal flameout
    Managing the flow of gas
    Auto-flaming and extinguishing
    Temperature control technology of graphite furnace advanced
    Introducing PID technology can effectively overcome the influence on the temperature rising procedure
    The combination of the 3ms/time fast sampling technique can result in more accurate and dependable testing data
    The fast heating capacity can improve the elements' flexibility even more
    Use a standard 220V power source instead of a 380V dynamic power source
    The maximum procedure heating capacity setting of 20 levels can make testing multiple samples more efficient and comfortable
    Three grades of adjustable gas flow can be tailored to meet a variety of application requirements
    Can provide a timely warning when the gas and water are turned off and there is insufficient gas and water, thereby avoiding equipment damage and measurement error
    Safe, reliable, and convenient flame system
    EPC can more precisely control the flow of acetylene (C2H2) and is a type of system that is also simple to operate
    A well-functioning Tomi Ziti on the system allows for greater sensitivity
    The entire operating system is highly secure because the fire safety system scan alert for the fluctuation
    It will also automatically turn off the gas and prohibit temper tantrums
    Protects the operating personnel and equipment from harm and damage
    Multi-functional software workstation, a working computer that is supported WINDOWS XP/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000
    The extensive menu makes it easy for customers to use
    Easy conversion between different menus simplifies the operation
    A variety of analytical correction methods gives users more options
    The basic default parameter settings allow even inexperienced users to perform routine operations
    Flexible storage, editing, and printing methods provide the most support to the user